| Operating temperature | -40℃ - 85℃ |
| Storage temperature | -40℃ - 105℃ |
| Operating humidity | 5%-95% |
| Storage humidity | 5%-95% |
| Operating altitude | < 5000m |
| IP level | IP41 |
| Lifetime | ≥15 Years |
| Flame rating (housing & connectors) | UL94V0 |
| Dimension | BMS: 150*120*300 mm |
| Operating voltage | 9V - 16V |
| Rated operating current | ≤120mA @ 13.5V |
| Quiescent current | ≤0.2mA @ 13.5V |
| Cell voltage measurement | Number | 12s - 14s |
| Range | 0V - 5V | |
| Accuracy | ≤±3mV @0.3V - 5V, -40℃ - 85℃ | |
| Cell temperature measurement | Number | 4 temperature channels |
| Range | -40°C - 125°C | |
| Accuracy | ±3°C @ -40°C - 85°C ±4°C @ 85°C - 125°C | |
| Balancing control | Balancing current | 100mA @ 3.65V |
| Method | passive balancing | |
| 48V measurement | Number | 2 channels |
| Range | 0V - 80V | |
| Accuracy | ≤±0,5% | |
| Current measurement | Mode | Shunt measurement |
| Range | -500A - 500A | |
| Accuracy | ± 0,5% | |
| Shunt NTC measurement | Number | 1 |
| Range | -40°C - 150°C | |
| Accuracy | ± 3°C @ -40°C - 130°C ± 5°C @ 130°C - 150°C | |
| SoX management | SOC accuracy | ≤ ±5% |
| SOH accuracy | ≤ ±5% | |
| SOE accuracy | ≤ ±5% | |
| Communication and diagnosis | CAN Communication | CANFD |
| UDS | Supported | |
| OBD | Supported | |
| XCP | Supported | |
| Battery protection | Method | OV/UV, OT, OC protection |
| Cyber security | Level | Capability up to CAL 2 |
| FUSA | ASIL level | Capability up to ASIL D |
| OTA | Method | A/B swap |
| AutoSAR | Version | 4.x |
| Wake up | CAN wakeup | Support for specific frame wakeup |
| AFE wakeup | Host wakeup when OV/UV/OT happen in sleep mode | |
| RTC timed wakeup | Supported | |
| Circuit breaker | Control type | HSD control |
| Technology | Semiconductor (MosFET switch) |